- Complies with ISO DIS 8041 (2003), ISO 2631: Part 1 (1997), ISO 2631 Part 2 (2003), ISO 2631: Part 4 (2001)
- Measures rms, rms average, MTVV (maximum transient vibration value), VDV, crest factor and peak in x, y and z directions
- Frequency weightings wb, wd, wm, wk, wc and wj can be independently set on each channel, along with multiplication factor
- Measurement times:
- manual start/stop
- 1 30 seconds in 1 second steps
- 1, 5, 10, 15and 30 minutes
- 1, 4, 8 and 12 hours
- Auto-stores up to 12 hrs worth of 1 second logged data (rms, VDV and Peak) for each channel
- Manual storage for 50 000 datasets onto card
- Measurement Ranges with PV-62 (seat accelerometer) 0.3, 1, 3, 10, 30, 100, 300, 1000 ms-2
|